Novel Single-Site Device for Conjoined Glucose Sensing and Insulin Infusion: Performance Evaluation in Diabetes Patients During Home-Use.

dc.creatorTschaikner, Mathias
dc.creatorPowell, Kevin
dc.creatorJungklaus, Miro
dc.creatorFritz, Martin
dc.creatorEllmerer, Martin
dc.creatorHovorka, Roman
dc.creatorLane, Steve
dc.creatorPieber, Thomas R
dc.creatorRegittnig, Werner
dc.date2019-07-01T23:30:47Z
dc.date2019-07-01T23:30:47Z
dc.date2020-01
dc.date.accessioned2026-08-03T03:36:53Z
dc.descriptionOBJECTIVE: This study evaluated a novel diabetes treatment device that combines commercially available continuous glucose monitoring and insulin infusion technology in such a way as to perform insulin delivery and glucose sensing through a single skin insertion site (single-port device). METHODS: Ten type 1 diabetes patients used the device for up to six days in their home/work environment for open-loop insulin delivery and glucose sensing. On an additional day, the device was used in combination with an algorithm to perform automated closed-loop glucose control under hospital settings. To assess the performance of the device, capillary blood glucose concentrations were frequently determined and a continuous glucose sensor was additionally worn by the patients. RESULTS: The average mean absolute relative deviation from blood glucose concentrations obtained for the sensor of the device was low (median, 13.0%; interquartile range, 10.5-16.7%; n = 10) and did not differ from that of the additionally worn glucose sensor (versus 13.9%; 11.9-15.3%; P = 0.922). Furthermore, insulin delivery with the single-port device was reliable and safe during home use and, when performed in combination with the control algorithm, was adequate to achieve and maintain near normoglycemia. CONCLUSION: Our data show the feasibility of open- and closed-loop glucose control in diabetes patients using a device that combines insulin delivery and glucose sensing at a single tissue site. SIGNIFICANCE: The reduction in device size and invasiveness achieved by this design may largely increase patient convenience and enhance acceptance of diabetes treatment with continuous glucose monitoring and insulin delivery technology.
dc.formatPrint-Electronic
dc.formatapplication/pdf
dc.identifier0018-9294
dc.identifierhttps://www.repository.cam.ac.uk/handle/1810/294261
dc.identifier10.17863/CAM.41360
dc.identifier1558-2531
dc.identifier.urihttps://repo.dare.co.zw/handle/123456789/178642
dc.languageeng
dc.languageeng
dc.publisherInstitute of Electrical and Electronics Engineers (IEEE)
dc.publisherhttps://doi.org/10.1109/tbme.2019.2925434
dc.rightsAll rights reserved
dc.rightshttp://purl.org/NET/rdflicense/allrightsreserved
dc.subjectAdolescent
dc.subjectAdult
dc.subjectAged
dc.subjectBlood Glucose
dc.subjectBlood Glucose Self-Monitoring
dc.subjectDiabetes Mellitus, Type 1
dc.subjectFemale
dc.subjectHumans
dc.subjectHypoglycemic Agents
dc.subjectInsulin
dc.subjectInsulin Infusion Systems
dc.subjectMale
dc.subjectMiddle Aged
dc.subjectPancreas, Artificial
dc.subjectYoung Adult
dc.titleNovel Single-Site Device for Conjoined Glucose Sensing and Insulin Infusion: Performance Evaluation in Diabetes Patients During Home-Use.
dc.typeArticle